Mitsubishi PLC-FX2N-64MR

৳ 0.00

Mitsubishi PLC-FX2N-64MR

 

Brand:
Mitsubishi
Model: FX2N-64MR
Origin: Japan
Input: 32 Points
Output: 32 Points
Power: 220V AC
Spread the love

Description

Mitsubishi PLC-FX2N-64MR FX2N series Mitsubishi PLC is compact device with built in I/O’s offer offer’s extremely fast programming execution and provide maximum flexibility. Mitsubishi PLC-FX2N-64MR has 64 built in I/O points can expendable up to 256 points, 32 digital inputs and 32 relay type outputs. Relay outputs rated 240VAC or 30 VDC up to 2 Amp per point max. 24Vdc which can configure sink/source. 8k program capacity 27 basic instructions.60 Hz high speed counters  and real time clock are available. Built in run/stop switch is available. High processing speed, 0.08μs/basic instruction 125 applied instructions, 3072 auxiliary relays, 256 timers, 235 counters. 8000 data registers.

World Automation and Engineering is the biggest sealer of Mitsubishi PLC and accessories in Bangladesh. We have whole sale and retail both convenience method to purchase your best deal. We provide 12 months warranty on our every product and also provide after sale support and services. Delivery service are also available via courier, we deliver our product via Sundarban Courier Service and SA Paribahan all over Bangladesh. For requirement of any other information feel free to contact With WhatsApp. WhatsApp No: +88 01759 659025.

Product Specification of Mitsubishi PLC-FX2N-64MR:

Model FX2N-64MR
Digital Input 32  point
Digital Output 32 Point
Output Type Relay
Supply Voltage 100-240VAC
Power Consumption 60VA
Shipping Weight 3 Kg
Communication Port Type:
RS232, RS422, RS485.
Program Capacity:
8000 Steps
Programming Interface: Computer, GX-Developer, GX Works2 
Maximum Operating Temperature: +55°C
Dimensions:  90 x 220 x 87 mm
Battery Backup: Yes
Mounting Type: DIN Rail

 

Performance Specification of The FX2N(C):

Item Specification Remarks
Operation control method Cyclic operation by stored program
I/O control method Batch processing method (when END instruction is executed) I/O refresh instruction is available
Operation processing time Basic instructions: 0.08 µs Applied instructions: several 10’s to 100 µs
Programming language Relay symbolic language + step ladder Step ladder can be used to produce an SFC style program
Program capacity 8000 steps built in Expandable to 16000 steps using additional memory cassette
Number of instructions Basic sequence instructions: 20 Step ladder instructions: 2 Applied instructions: 125 A Maximum 125 applied instructions are available
I/O configuration Max hardware I/O configuration points 255, dependent on user selection (Max. software addressable Inputs 255, Outputs 255)
Auxiliary relay (M coils) Genera 3072 points M0 to M3071
Latched 2572 points (subset) M0 to M3071
Special 256 points From the range M8000 to M8255
State relays (S coils) General 1000 points S0 to S999
Latched 500 points (subset) S500 to S999
Initial 10 points (subset S0 to S9
Annunciator 100 points S900 to S999
Timers (T) 100 msec Range: 0 to 3,276.7 sec 200 points T0 to T199
10 msec Range: 0 to 327.67 sec 46 points T200 to T245
1 msec retentive Range: 0 to 32.767 sec 4 points T246 to T249
100 msec retentive Range: 0 to 3,276.7 sec 6 points T250 to T255
Counters (C) General 16 bit Range: 1 to 32,767 counts 200 points C0 to C199 Type: 16 bit up counter
Latched 16 bit 100 points (subset) C100 to C199 Type: 16 bit up counter
General 32 bit Range: -2,147,483,648 to 2,147,483,647 35 points C200 to C234 Type: 32 bit up/down counter
Latched 32 bit 15 points (subset) C219 to C234 Type: 16 bit up/down counter
High speed counters (C) 1 phase Range: -2,147,483,648 to +2,147,483,647 counts General rule: Select counter combinations with a combined counting frequency of 20kHz or less. Note all counters are latched C235 to C240 6 points
1 phase c/w start stop input C241 to C245 5 points
2 phases C246 to C250 5 points
A/B phase C251 to C255 5 points
Data registers (D) General 8000 points D0 to D7999 Type: 16 bit data storage register pair for 32 bit device
Latched 7800 points (subset) D200 to D7999 Type: 16 bit data storage register pair for 32 bit device
File registers 7000 points D1000 to D7999 set by parameter in 14 blocks of 500 program steps Type: 16 bit data storage register
Special 256 points From the range D8000 to D8255 Type: 16 bit data storage register
Index 16 points V0 to V7 and Z0 to Z7 Type: 16 bit data storage register
Pointers (P) For use with CALL 128 points P0 to P127
For use with interrupts 6 input points, 3 timers, 6 counters I00 to I50 and I6 to I8 (rising trigger =1, falling trigger =0, =time in msec)
Nest levels   8 points for use with MC and MCR N0 to N7
Numbers Decimal K 16 bit: -32,768 to +32,767 32 bit: -2,147,483,648 to +2,147,483,647
Hexadecimal H 16 bit: 0000 to FFFF 32 bit: 00000000 to FFFFFFFF
Floating Point 32 bit: 0, ±1.175 x 10-38, ±3.403 x 1038 (Not directly enterable)

 

 